| Age | Commit message (Collapse) | Author |
|
Althoug the MTIMER part of a C9xx CLINT differs from a SiFive one, the
MSWI part is compliant.
Add T-Head C9xx CLINT compatible string to fdt_ipi_mswi code, sharing
the same codepath with SiFive CLINT.
Signed-off-by: Icenowy Zheng <[email protected]>
Reviewed-by: Anup Patel <[email protected]>
|
|
Move Andes PLICSW ipi device to fdt ipi framework, this patch is based
on Leo's modified IPI scheme on PLICSW.
Current IPI scheme uses bit 0 of pending reigster on PLICSW to send IPI
from hart 0 to hart 7, but bit 0 needs to be hardwired to 0 according
to spec. After some investigation, self-IPI seems to be seldom or never
used, so we re-order the IPI scheme to support 8 core platforms.
dts example (Quad-core AX45MP):
plicsw: interrupt-controller@e6400000 {
compatible = "andestech,plicsw";
reg = <0x00000000 0xe6400000 0x00000000 0x00400000>;
interrupts-extended = <&CPU0_intc 3
&CPU1_intc 3
&CPU2_intc 3
&CPU3_intc 3>;
interrupt-controller;
#address-cells = <2>;
#interrupt-cells = <2>;
};
Signed-off-by: Yu Chien Peter Lin <[email protected]>
Reviewed-by: Anup Patel <[email protected]>
|
|
We update FDT support makefile to use kconfig for enabling/disabling.
To avoid compilation errors, we also enable FDT for each platform.
Signed-off-by: Anup Patel <[email protected]>
Tested-by: Andrew Jones <[email protected]>
Acked-by: Atish Patra <[email protected]>
Tested-by: Atish Patra <[email protected]>
|
|
We update ipi drivers makefile to use kconfig for enabling/disabling
drivers. To avoid compile errors, we also enable appropriate ipi
drivers for each platform.
Signed-off-by: Anup Patel <[email protected]>
Tested-by: Andrew Jones <[email protected]>
Acked-by: Atish Patra <[email protected]>
Tested-by: Atish Patra <[email protected]>
|
|
The allwinner,sun20i-d1-clint compatible string is not documented in any
official binding, so it should not be used by drivers.
The MSWI in the D1 CLINT is compatible with the ACLINT specification, so
it can take advantage of generic driver support. However, that is only
possible if the MSWI and MTIMER are split into separate DT nodes. This
means the final binding for this device is likely to be incompatible
with what is implemented here.
Remove this compatible string from the driver to prevent it from
appearing in a stable version and causing future issues.
Signed-off-by: Samuel Holland <[email protected]>
Reviewed-by: Anup Patel <[email protected]>
|
|
The CLINT in the Allwinner D1 SoC apparently does not support 64-bit
MMIO access. A property was added to support this quirk (and that
property was copied to the ACLINT MTIMER code). However, since this
difference in behavior makes the D1 CLINT incompatible with the SiFive
CLINT's programming interface, a better solution is to use a separate
compatible string.
Signed-off-by: Samuel Holland <[email protected]>
Reviewed-by: Anup Patel <[email protected]>
|
|
Match data stores hardware attributes which do not change at runtime, so
it does not need to be mutable. Make it const.
Reviewed-by: Guo Ren <[email protected]>
Reviewed-by: Xiang W <[email protected]>
Reviewed-by: Anup Patel <[email protected]>
Signed-off-by: Samuel Holland <[email protected]>
|
|
Instead of having FDT ipi driver list hard-coded in the C source,
we generate it using carray.sh at compile-time.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Atish Patra <[email protected]>
|
|
Currently, the ACLINT MSWI size check is forcing size to be at least
0x4000. This is inappropriate check because most systems will never
utilize full 16KB for a single ACLINT MSWI device so instead we should
check that ACLINT MSWI size is enough for on the associated HARTs.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Dong Du <[email protected]>
Reviewed-by: Alistair Francis <[email protected]>
|
|
This simply adds an helper to get fdt address which is more explicit than
sbi_scratch_thishart_arg1_ptr.
Signed-off-by: Alexandre Ghiti <[email protected]>
Reviewed-by: Xiang W <[email protected]>
Reviewed-by: Anup Patel <[email protected]>
|
|
The fdt_parse_aclint_node() is used to parse DT node for SiFive
CLINT, ACLINT MTIMER, and ACLINT MSWI devices.
The ACLINT MTIMER has undergone following changes:
1) MTIMER DT node now requires separate addresses in for MTIME
register and MTIMECMPx registers in the reg DT property.
2) MTIMER DT node might have no interrupts-extended DT property
when the MTIMER device has no associated HARTs (i.e. the
MTIMER device has no MTIMECMPx registers)
This patch extends fdt_parse_aclint_node() to handle above
mentioned changes in ACLINT MTIMER DT bindings.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Atish Patra <[email protected]>
|
|
We add a new FDT based ACLINT MSWI IPI driver which works for both
CLINT device and standalone ACLINT MSWI device.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Bin Meng <[email protected]>
Reviewed-by: Xiang W <[email protected]>
|
|
We add fdt_parse_aclint_node() which can parse both ACLINT and
CLINT DT nodes. This means fdt_parse_clint_node() is not required
anymore so we remove it as well.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Bin Meng <[email protected]>
Reviewed-by: Xiang W <[email protected]>
|
|
We add common ACLINT MSWI library similar to the CLINT library
so that OpenSBI platforms can use it.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Bin Meng <[email protected]>
Reviewed-by: Xiang W <[email protected]>
|
|
We should try other FDT drivers when we see SBI_ENODEV returned
by cold_init() of FDT driver.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Atish Patra <[email protected]>
Reviewed-by: Xiang W <[email protected]>
|
|
Instead of having ipi_send() and ipi_clear() callbacks in
platform operations, it will be much simpler for ipi driver
to directly register these operations as a device to sbi_ipi
implementation.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Alistair Francis <[email protected]>
|
|
Linux kernel commit a2770b57d083 ("dt-bindings: timer: Add CLINT bindings")
adds the official DT bindings for CLINT, which uses "sifive,clint0"
as the compatible string. "riscv,clint0" is now legacy and has to
be kept for backward compatibility of legacy systems.
Signed-off-by: Bin Meng <[email protected]>
Reviewed-by: Anup Patel <[email protected]>
|
|
We can have multiple matching DT nodes of the same FDT ipi driver
so in this case we should call cold_init() for all matching DT nodes
instead of just first matching DT node.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Atish Patra <[email protected]>
|
|
We add fdt_parse_clint_node() function which will be used by
fdt_ipi_clint and fdt_timer_clint drivers to parse CLINT details
from DT node.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Atish Patra <[email protected]>
|
|
We extend CLINT cold init function to have a "struct clint_data *"
parameter pointing to CLINT details. This allows platforms to use
CLINT functions for multiple CLINT instances.
When multiple CLINTs are present, the platform can also provide
one of the CLINT as reference CLINT for other CLINTs. This will
help CLINTs to sync their time value with reference CLINT using
a time_delta computed in warm init function.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Atish Patra <[email protected]>
|
|
We extend fdt_find_match() implementation by adding node offset
parameter which represents the first node to match from.
The improved fdt_find_match() can be used to find multiple
match nodes.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Atish Patra <[email protected]>
|
|
We add simple ipi framework which will select and use ipi driver
based on details in FDT passed by previous booting stage.
Signed-off-by: Anup Patel <[email protected]>
Reviewed-by: Atish Patra <[email protected]>
|