<title>dm: pmic: Display the regulator limits on error</title>
<updated>2015-08-06T03:06:13+00:00</updated>
<author>
<name>Simon Glass</name>
<email>sjg@chromium.org</email>
</author>
<published>2015-07-03T00:16:07+00:00</published>
<link rel='alternate' type='text/html' href='http://cgit.235523.xyz/u-boot.git/commit/?id=224d1ddcc5fa18d88e2c735778c39b8df61016ea'/>
<id>224d1ddcc5fa18d88e2c735778c39b8df61016ea</id>
<content type='text'>
When a regulator command cannot honour the requested voltage, display the
limits to try to be helpful.

Signed-off-by: Simon Glass &lt;sjg@chromium.org&gt;
Acked-by: Przemyslaw Marczak &lt;p.marczak@samsung.com&gt;
</content>
<content type='xhtml'>
<div xmlns='http://www.w3.org/1999/xhtml'>
<pre>
When a regulator command cannot honour the requested voltage, display the
limits to try to be helpful.

Signed-off-by: Simon Glass &lt;sjg@chromium.org&gt;
Acked-by: Przemyslaw Marczak &lt;p.marczak@samsung.com&gt;
</pre>
</div>
</content>
</entry>
<entry>
<title>common: cmd regulator: command cleanup</title>
<updated>2015-05-15T01:58:34+00:00</updated>
<author>
<name>Przemyslaw Marczak</name>
<email>p.marczak@samsung.com</email>
</author>
<published>2015-05-13T11:38:29+00:00</published>
<link rel='alternate' type='text/html' href='http://cgit.235523.xyz/u-boot.git/commit/?id=e09b2a02d3b0061c7532b6fa175c8506f36541eb'/>
<id>e09b2a02d3b0061c7532b6fa175c8506f36541eb</id>
<content type='text'>
This commit cleanups the regulator command.
The first change, is adjusting "regulator dev" command to use
"regulator-name" constraint, for setting the operating device.
Thanks to this, the regulator_get() function is removed.

This also updates do_list() function, with loop over uclass_find_*
function calls, to prevent probe of all listed regulators.

This also cleanups the printing in command.

Signed-off-by: Przemyslaw Marczak &lt;p.marczak@samsung.com&gt;
Acked-by: Simon Glass &lt;sjg@chromium.org&gt;
Tested on sandbox:
Tested-by: Simon Glass &lt;sjg@chromium.org&gt;
</content>
<content type='xhtml'>
<div xmlns='http://www.w3.org/1999/xhtml'>
<pre>
This commit cleanups the regulator command.
The first change, is adjusting "regulator dev" command to use
"regulator-name" constraint, for setting the operating device.
Thanks to this, the regulator_get() function is removed.

This also updates do_list() function, with loop over uclass_find_*
function calls, to prevent probe of all listed regulators.

This also cleanups the printing in command.

Signed-off-by: Przemyslaw Marczak &lt;p.marczak@samsung.com&gt;
Acked-by: Simon Glass &lt;sjg@chromium.org&gt;
Tested on sandbox:
Tested-by: Simon Glass &lt;sjg@chromium.org&gt;
</pre>
</div>
</content>
</entry>
<entry>
<title>dm: regulator: add regulator command</title>
<updated>2015-05-15T00:49:37+00:00</updated>
<author>
<name>Przemyslaw Marczak</name>
<email>p.marczak@samsung.com</email>
</author>
<published>2015-04-20T18:07:44+00:00</published>
<link rel='alternate' type='text/html' href='http://cgit.235523.xyz/u-boot.git/commit/?id=6262b72b8beff316eefc673e1a45ecfee76c9cb1'/>
<id>6262b72b8beff316eefc673e1a45ecfee76c9cb1</id>
<content type='text'>
This command is based on driver model regulator's API.
The user interface provides:
- list UCLASS regulator devices
- show or [set] operating regulator device
- print constraints info
- print operating status
- print/[set] voltage value [uV] (force)
- print/[set] current value [uA]
- print/[set] operating mode id
- enable the regulator output
- disable the regulator output

The 'force' option can be used for setting the value which exceeds
the constraints min/max limits.

Signed-off-by: Przemyslaw Marczak &lt;p.marczak@samsung.com&gt;
Acked-by: Simon Glass &lt;sjg@chromium.org&gt;
</content>
<content type='xhtml'>
<div xmlns='http://www.w3.org/1999/xhtml'>
<pre>
This command is based on driver model regulator's API.
The user interface provides:
- list UCLASS regulator devices
- show or [set] operating regulator device
- print constraints info
- print operating status
- print/[set] voltage value [uV] (force)
- print/[set] current value [uA]
- print/[set] operating mode id
- enable the regulator output
- disable the regulator output

The 'force' option can be used for setting the value which exceeds
the constraints min/max limits.

Signed-off-by: Przemyslaw Marczak &lt;p.marczak@samsung.com&gt;
Acked-by: Simon Glass &lt;sjg@chromium.org&gt;
</pre>