platform: starfive: get I2C offset address from clocks property
The current code gets the I2C offset address using the device tree node
name: it get the I2C device index from the 4th character in the node
name (for example, "i2c5" -> i2c device 5). However, the device tree
node's name in U-Boot is actually just "i2c" without the number, so the
current code cannot be used with the device tree from U-Boot.
Get the I2C offset address from the "clocks" property instead.
Signed-off-by: Nam Cao <[email protected]>
Reviewed-by: Minda Chen <[email protected]>
Tested-by: Minda Chen <[email protected]>
Reviewed-by: Anup Patel <[email protected]>
| -rw-r--r-- | platform/generic/starfive/jh7110.c | 24 |
1 files changed, 14 insertions, 10 deletions
diff --git a/platform/generic/starfive/jh7110.c b/platform/generic/starfive/jh7110.c index 4b221750..efa4029f 100644 --- a/platform/generic/starfive/jh7110.c +++ b/platform/generic/starfive/jh7110.c @@ -29,7 +29,7 @@ struct pmic { struct jh7110 { u64 pmu_reg_base; u64 clk_reg_base; - u32 i2c_index; + u32 i2c_clk_offset; }; static struct pmic pmic_inst; @@ -67,7 +67,6 @@ static u32 selected_hartid = -1; #define AXP15060_POWER_OFF_BIT BIT(7) #define AXP15060_RESET_BIT BIT(6) -#define I2C_APB_CLK_OFFSET 0x228 #define I2C_APB_CLK_ENABLE_BIT BIT(31) static int pm_system_reset_check(u32 type, u32 reason) @@ -163,10 +162,7 @@ static void pmic_i2c_clk_enable(void) unsigned long clock_base; unsigned int val; - clock_base = jh7110_inst.clk_reg_base + - I2C_APB_CLK_OFFSET + - (jh7110_inst.i2c_index << 2); - + clock_base = jh7110_inst.clk_reg_base + jh7110_inst.i2c_clk_offset; val = readl((void *)clock_base); if (!val) @@ -241,7 +237,8 @@ static struct fdt_reset fdt_reset_pmic = { static int starfive_jh7110_inst_init(void *fdt) { int noff, rc = 0; - const char *name; + const fdt32_t *val; + int len; u64 addr; noff = fdt_node_offset_by_compatible(fdt, -1, "starfive,jh7110-pmu"); @@ -261,9 +258,16 @@ static int starfive_jh7110_inst_init(void *fdt) } if (pmic_inst.adapter) { - name = fdt_get_name(fdt, pmic_inst.adapter->id, NULL); - if (!sbi_strncmp(name, "i2c", 3)) - jh7110_inst.i2c_index = name[3] - '0'; + /* + * The clocks property looks like this: + * clocks = <&syscrg JH7110_SYSCLK_I2C5_APB>; + * + * So, check that the length is 8 bytes, and get + * the offset from the second value. + */ + val = fdt_getprop(fdt, pmic_inst.adapter->id, "clocks", &len); + if (val && len == 8) + jh7110_inst.i2c_clk_offset = fdt32_to_cpu(val[1]) << 2; else rc = SBI_EINVAL; } |