summaryrefslogtreecommitdiff
path: root/src/typec
diff options
context:
space:
mode:
authorBoris Dolgov <[email protected]>2026-05-15 21:28:21 +0200
committerBoris Dolgov <[email protected]>2026-05-15 21:28:21 +0200
commit72e09788e46a8ffaaae8009a316915838927af90 (patch)
treefe386a6dc4b227a7e72411068fd07fa96537d9a6 /src/typec
parent7f146c9ff6e3aa6b19887b2b64161ae93f543888 (diff)
rp2040: fix host SET_REPORT (and any OUT-data control xfer) sending DATA0 instead of DATA1
hcd_edpt_xfer() previously reset ep->next_pid to 1 only when the control endpoint direction changed between stages. That handled IN-data control transfers (e.g. GET_REPORT, GET_DESCRIPTOR) where SETUP is OUT and DATA is IN, but not OUT-data class requests like SET_REPORT, where SETUP and DATA are both OUT and the direction-change check is false. ep->next_pid was left at 0 from hcd_edpt_open(), so the DATA stage went on the wire as DATA0 when the device expected DATA1. Strict devices (observed: Elgato Stream Deck) treat this as a protocol violation and disconnect. Key off "endpoint 0" instead of "direction changed", restoring the previous behavior. Interrupt/bulk endpoints take the ep->interrupt_num > 0 branch above and never reach this code, so they are unaffected.
Diffstat (limited to 'src/typec')
0 files changed, 0 insertions, 0 deletions