imx: ventana: put LTC3676 regulators in continuous mode
In the default pulse-skipping mode regulators that are very lightly
loaded can fail to regulate properly. Switching them to always use
continuous mode causes only around 10mW of overall system power
difference in a lightly loaded system that isn't already operating
them in continuous mode.
Signed-off-by: Tim Harvey <[email protected]>